文章摘要
YANG Qianqian,ZHANG Xuzhi,JIANG Xiaoyu,LI Yang,ZHAO Jun,HAO Zhihui,WANG Pingping,QU Keming.Direct Detection of Target Genes in Viable Bacteria and Extracellular DNA Using Loop-Mediated Isothermal Amplification Assay.渔业科学进展,2020,41(2):41-50
Direct Detection of Target Genes in Viable Bacteria and Extracellular DNA Using Loop-Mediated Isothermal Amplification Assay
Direct Detection of Target Genes in Viable Bacteria and Extracellular DNA Using Loop-Mediated Isothermal Amplification Assay
投稿时间:2019-02-20  修订日期:2019-03-05
DOI:
中文关键词: Loop-mediated isothermal amplification  DNA extraction-free  Direct gene detection  Viable cell  Extracellular DNA
英文关键词: Loop-mediated isothermal amplification  DNA extraction-free  Direct gene detection  Viable cell  Extracellular DNA
基金项目:
作者单位
YANG Qianqian College of Marine Sciences, Shanghai Ocean University, Shanghai 201306
Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071 
ZHANG Xuzhi Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071 
JIANG Xiaoyu College of Marine Sciences, Shanghai Ocean University, Shanghai 201306
Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071 
LI Yang Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071 
ZHAO Jun Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071 
HAO Zhihui School of Chemistry and Pharmaceutical Sciences, Qingdao Agriculture University, Qingdao 266109 
WANG Pingping School of Chemistry and Pharmaceutical Sciences, Qingdao Agriculture University, Qingdao 266109 
QU Keming Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071 
摘要点击次数: 2385
全文下载次数: 2934
中文摘要:
      When the loop-mediated isothermal amplification (LAMP) assay is used for detecting target genes, DNA extraction is unnecessary in many cases. Simple pretreatment (e.g. heating) is enough to obtain rather sensitive responses. Even test samples without any pretreatment can be used as template. This feature suggests that LAMP is superior to PCR in developing point-of-care test strategies. In this study, using Stx1 gene from E. coli as model, we verified that viable cells, dead cells and extracellular DNA could function as template in the LAMP assay. In the incubation at 63℃, viable bacteria in the LAMP reaction mixture lysed completely within 2 min, providing DNA template for nucleic acid amplification. The Stx1 gene in diluted culture medium, spiked tap water, spiked seawater and real seawater all could be detected, with or without the step of DNA extraction. We found that the complex substances in real sample (e.g. natural seawater) exhibited considerable inhibitory effect on the sensitivity of the LAMP assay. These outcomes are meaningful for building a point-of-care strategy by employing the LAMP assay for environmental monitoring, bio-resource surveys, food safety, etc. in particular those based on environmental DNA.
英文摘要:
      When the loop-mediated isothermal amplification (LAMP) assay is used for detecting target genes, DNA extraction is unnecessary in many cases. Simple pretreatment (e.g. heating) is enough to obtain rather sensitive responses. Even test samples without any pretreatment can be used as template. This feature suggests that LAMP is superior to PCR in developing point-of-care test strategies. In this study, using Stx1 gene from E. coli as model, we verified that viable cells, dead cells and extracellular DNA could function as template in the LAMP assay. In the incubation at 63℃, viable bacteria in the LAMP reaction mixture lysed completely within 2 min, providing DNA template for nucleic acid amplification. The Stx1 gene in diluted culture medium, spiked tap water, spiked seawater and real seawater all could be detected, with or without the step of DNA extraction. We found that the complex substances in real sample (e.g. natural seawater) exhibited considerable inhibitory effect on the sensitivity of the LAMP assay. These outcomes are meaningful for building a point-of-care strategy by employing the LAMP assay for environmental monitoring, bio-resource surveys, food safety, etc. in particular those based on environmental DNA.
附件
查看全文   查看/发表评论  下载PDF阅读器
关闭